Lutron PPS-9312 Pressure Controlle/Monitor

Lutron PPS-9312 Pressure Controlle/Monitor

Lutron PPS-9312 Pressure Controlle/Monitor

Features
* Meter connects with 2, 5, 10, 20, 50, 100, 200, 400 bar sensor, no calibration procedures are necessary typically when change a new sensor .
* Unit select : Bar, PSI, Kg/cm^2, inch Hg, mm Hg, inch H2O, meter H2O, Atmosphere, hPa, KPa.
* Large red LED display, high brightness and easy to read.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Alarm Relay will make action when the reading value reach to high/low alarm value.
* Control Relay will make action when the reading value reach to control value.
* Hysteresis value setting for control and alarm function.
* Microprocessor circuit ensures high accuracy and provides special functions and features.
* Power : 90 ACV to 260 ACV, 50/60 Hz.
* Cooperate the 4-20 mA pressure input, sensor can install in the faraway position.
* DC 24V output, used for the power of pressure sensor.
* RS-232/USB computer interface.
* DIN size : 96 x 48 mm. Depth : 110 mm.
* Optional pressure sensor, TR-PS2W-xxBAR, PS93MA-xxBAR.
* Optional USB cable, USB-01.
* Optional data acquisition software.
* Optional GSM controller.

Specification
Display :4 digits red LED, digit size : 14 mm. x 10, x100 indicator
Circuit :Custom chip of microprocessor LSI circuit.
Sensor type :Can cooperate with optional 2, 5, 10, 20, 50, 100, 200, 400 bar two wires 4 to 20 mA pressure sensor, new calibration are not necessary typically when change the new sensor .
* Sensor type can make the internal setting with default
Display units :Bar, Psi, Kg/cm^2, mm Hg, inch Hg, meter H2O, inch H2O, Atmosphere, hPa, KPa.
* Unit can make the internal setting with default
Accuracy :± ( 0.5% + 2 d )
* Meter only.
* Within 23 ℃± 5 ℃
Pressure Sensor :Cooperate the optional two wires ( or four wires ) 4 to 20 mA pressure sensors ( transmitters ).
* optional :* two wires sensor : TR-PS2W-xxBAR
* Four wires sensor : PS93MA-xxBAR
Offset adjust :It can make the internal Offset setting with default.
Gain adjust :It can make the internal Gain setting with default
Input signal from sensor :* Input 4 mA = 0 pressure, * Input 20 mA = full scale pressure
Sampling Time :Approx. 1 second.
External power supply :DC 24 V, 50 mA max.
Data Output :RS 232 PC serial interface.
Operating TEmp:0 to 50 ℃.
Operating Humidity :Less than 80% R.H.
Power Supply 90 to 260 ACV, 50/60 Hz.
Power Consumption :Approx. 7.3 VA/AC 110V. Approx. 11 VA/AC 220V.
Weight :258 g/0.57 LB.
Dimension :DIN size : 96 x 48 mm. Depth : 110 mm.
Accessories Included :Instruction manual, Case holder with screw
Optional Accessories :Two wires pressure transmitters,Model : TR-PS2W-xx BAR
* Range : 2, 5, 10, 20, 50, 100 400 BAR.
* Data Acquisition software, SW-U801-WIN.
* RS232 cable, UPCB-02.
* USB cable, USB-01.
* Real time SD card datalogger DL-9602SD
* GSM controller, GSM-889.
* Interface cable ( cable between meter to GSM-889 ), GMCB-89.

We do undertake Servicing and repairing of Lutron PPS-9312 Pressure Controlle/Monitor lutron Range of products throughout india

Apart from supplying lutron Electrical Testing products in India through dealers network, catering to a variety of customers ranging from Atomic energy, Electricity Boards, Electrical Laboratory, Shopping Complexes, Shopping Mall, Electrical Contractors, Engineering Industries, Turnkey Construction Companies, Railways, Defence Installations, Research Laboratories, Educational Institutes and various Research and Development laboratories of leading national and multinational companies.

We DFT TECH, are lutron Authorized Distributors, Importers, Stockists, Dealers and Suppliers of Lutron PPS-9312 Pressure Controlle/Monitor Products in Bagalkot, Bihar, Tiruvannamalai, Villupuram, Cuddalore, Dharwad, Delhi, Amristar, Tirupur, Vellore, Punjab, Chattisgarh, Jharkhand, Viruthachalam, Ambala, Dindugul, Chitoor and etc..