Konica Minolta CR-410C Coffee Index Colorimeter

Konica Minolta CR-410C Coffee Index Colorimeter

Konica Minolta CR-410C Coffee Index Colorimeter

Coffee we enjoy daily is made from powdered roasted coffee. Different roasted levels lead to different aroma, flavour and taste of coffee. The Speciality Coffee Association of Americas (SCAA) has systematically classified the Roasting degree into 8 levels.

Leading and exporting coffee powder manufacturers have replaced the traditional(visual) classification of roast levels by introducing the color measuring devices in their manufacturing units. Colour measurement for coffee by measuring color devices and show the results in the Pass/Fail format or give the result in L*a*b* format.

The color measurement is needed across all stages of coffee production – Sorting at entry level, Roasting at production and Grading during packaging.

Entry level – Color measurement devices are needed here to sort the coffee beans at the entry level. Only those coffee beans which carry the required color levels are picked and forwarded to the production stage. If all color variations are removed in this level, then consistent production is maintained and better yields are obtained at the final stage.

Production stage – The coffee bean goes through different stages during the entire Roasting process. The shift of the stage is done by checking the color of Roast. From green to dark brown the bean transforms from one color to another under different temperature changes. The change of heating temperature has to be done at the right time(when the color is correct) to get perfect results.

Features
Easy to use with one button calculation provides information without the hassle of printing
Agronomical design with provides maximum portability
Calculated measurements based coffee industry standard established by the Specialty Coffee Association of America (SCAA)
Can measure powder, instant, whole coffee beans, and lyophilized forms
Low-cost compared to the competition

Specification
Name :Chroma Meters Measuring Head
Illuminating/viewing system :Wide-area illumination/0° viewing angle; specular component included)
Detector :Silicon photocells (6)
Display range :Y: 0.01% to 160.00% (reflectance)
Light source :Pulsed xenon lamp
Measurement time :1 sec.
Minimum measurement interval :3 sec.
Battery performance :Approx. 800 measurements (when using batteries under Konica Minolta's testing conditions)
Measurement/illumination area :⌀ 50mm/ ⌀ 53mm
Repeatability :Within ΔE*ab 0.07 standard deviation
(when the white calibration plate is measured 30 times at intervals of 10 seconds)
Inter-instrument agreement ΔE*ab: Within 0.8
Average of 12 BCRA Series II colors
Observer :2° Closely matches CIE 1931 Standard Observer ( x2λ, yλ, zλ)
Illuminant *1 :C, D65
Display *1 :Chroma values, color difference values, PASS/WARN/FAIL display
Tolerance judgement *1 :Color difference tolerance (box tolerance and elliptical tolerance)
Color space/ colorimetric data :XYZ, Y x y, L*a*b*, Hunter Lab, L*C*h, Munsell (only illuminant C), CMC (l:c), CIE1994, Lab99,
LCh99, CIE2000, CIE WI-Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six can be registered from computer)
Languages *1 :Operating keys: English
LCD: English (default)
(LCD: German, French, Italian, Spanish, Japanese)
Storable data sets :1000 (measureing head and data processor save different data)
Color difference target colors 100
Calibration channels *1 :20 channels (ch00: white calibration, ch01 to ch19 : user calibration)
Display :Dot-matrix LCD with back light (15 chars x 9 lines + 1 line for icon display)
Interface :RS0232C compliant (for data processor/PC)
*Baud rate: 4800, 9600, 19200 (bps) set at 9600 bps when shipped from factory
Power source :4 AA size alkaline or Ni-MH batteries,
AC adapter AC120V 50-60Hz (for N.America and Japan)
AC230V 50-60Hz (for worldwide except N.America)
Size :410: 102 (W) x 244 (H) x 63 (D) mm
Weight :410: Approx 570g
(including 4 AAA size batteries and not including RS-232C cable)
Operating temperature/Humidity Range :0 to 40C, relative humidity 85% or less (at 35 C) with no condensation
* Operating temperature/humidity range of products for North America : 5 to 40 C, relative humidity 80% or less (at 31 C) with no condensation
Storage temperature/humidity range :-20 to 40 C, relative humidity 85% or less (at 35 C) with no condensation
Other :LCD back light ON/OFF function (when ON< back light stays ON for 30 seconds after last key or measuremment operation)

*1 indicates when connected to the Data Processor or when not set using the Data Processor or the optional software, that some of the function are not available when the measuring head is not connected.

Name :Data Processor
Model :DP-400
Display range :Y : 0.01 to 160.00% (reflectance)
Measurement time *2 :1 Seconds.
Minimum measurement interval *2 :3 Seconds.
Battery performance :Approx. 800 measurements (when using batteries under company testing Konica Minolta's conditions)
Illuminants C, D65
Display :Chroma values, color difference values, color difference graphs, PASS/WARN/FAIL display
Tolerance judgment *2 :Color difference tolerance (box tolerance and elliptical tolerance) Only for the display function
Color space/ colorimetric data :XYZ, Y x y, L*a*b*, Hunter Lab, L*C*h, Munsell (only illuminant C), CMC (l:c), CIE1994, Lab99,
LCh99, CIE2000, CIE WI-Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six registered in the Measuring Head can be used)
Languages :Operating keys : English, LCD : English (default), German, French, Italian, Spanish, Japanese
Storable data sets :Max. 2000 pieces of data (divisible into 100 pages)
Deletion and Undoing selected stored data (one piece of data or all data) are possible
Color difference target colors *2 :Only for the operating function (100 pieces of data when the measuring head is connected; input of measurement values or numeric) (independent of page function)
Calibration c:hannels *2 Only for the operating function (20 channels when the measuring head is connected)
(ch00: white calibration; ch01 to ch19: user calibration)
Page function :100 pages
Display :Dot-matrix LCD with back light (16 chars x 9 lines + 1 line for icon display) Contrast adjustment
Printer 384 dot line thermal printer (can also print graphs) Automatically prints out all measurement results (can be set not to print)
Statistical function :Maximum, minimum, average, and standard deviation
Automatic measurement *2 :Date and time display: year, month, day, hour, minute
Timer: 3seconds. to 99 minutes.
(Some measurement modes require more than 3 seconds.)
Interface :RS-232C compliant Baud rate (bps) : 19200 fixed (when connected to PC)
When measuring head is connected baud rate is automatically set to that of the measurement head
Power source :4 AA size alkaline or Ni-MH batteries,
AC adapter AC120V 50-60Hz (for N.America and Japan)
AC230V 50-60Hz (for worldwide except N.America)
Size :100(W) x 73(H) x 255(D)mm
Weight :Approx. 600g (not including batteries and paper)
Operating temperature/Humidity Range :0 to 40C, relative humidity 85% or less (at 35 C) with no condensation
* Operating temperature/humidity range of products for North America : 5 to 40 C, relative humidity 80% or less (at 31 C) with no condensation
Storage temperature/humidity range :-20 to 40 C, relative humidity 85% or less (at 35 C) with no condensation

Other User :calibration function (multi-calibration/manual calibration) ∗2, Measurements for automatic average function, Print ON/OFF function. CR-400 measurement data import function ∗2, All color space print ON/OFF function, Data protection ON/OFF function. Back light ON/OFF function. Buzzer ON/OFF function. Display color limit function, Remote mode (stored data output), Character input function (alphanumeric)

Packaging – The final roasted bean is again color checked for final grading. This helps the manufacturer to separate the coffee beans into categories of export, local consumptions or pricing.

Konica Minolta – CR 410 C uses the SCAA index to classify the roast levels. Many leading coffee manufacturers have greatly benefited by using this device.

Enquire with us on how we can bring improvement in the coffee production quality through color measurement.

Konica Minolta CR-410C Coffee Index Colorimeter konica-minolta-color-and-appearance-measurements Range of products are mostly available in ready stock and it can delivered immediately throughout india

Apart from supplying Konica Minolta products in India through dealers network, catering to a variety of customers ranging from Electrical Contractors, Engineering Industries, Turnkey Construction Companies, Railways, Defence Installations, Research Laboratories, Educational Institutes and various Research and Development laboratories of leading national and multinational companies.

We DFT TECH, are Suppliers of Konica Minolta Products in Chennai, Jamshedpur, Sriperambattur, Vadapalani, Aurangabad, Vijayawada, Amristar, Colachel, Ariyalur, Nagapattinam, Walajapettai, Kanpur, Simla, Nilagiri, Sivakasi, Jaipur and etc..