Being an Proclaimed manufacturers and Suppliers of Fully Automatic Digital Autoclaves in India since 1980. Our Fully Automatic Digital Autoclaves are mostly & widely used for everyday sterilization process methods in various Automated Pharmaceutical laboratories, Sophosticated Food Laboratories, Hitech Universities and for Research applications. We specialize in both standard, advanced, customized models with CE Marked, specifically designed to meet the challenging demands of various scientists / Research centers / individual and specialized research applications. Over a long period of time DFT Tech have been established as reliable Manufacturers, Exporters and Suppliers of Fully Automatic Digital Autoclaves in India, catering to the huge markets in Asia, Middle East,North America and South America, Australia, Africa and Europe. Apart from that we are supplying our Fully Automatic Digital Autoclavesin India through dealers , catering to a variety of customers ranging from Atomic energy, Biotechnology Companies, Microbiology Laboratory, Pharmaceutical Manufacturers, Defence Installations, Research Laboratories, Educational Institutes and various Research and Development laboratories of leading national and multinational companies.

We DFT Tech Manufacturers, Exporters, Suppliers and Distributors of the Fully Automatic Digital Autoclaves to various industries supplied our exclusive Scientific Dealers throughout in india

Advantages of Autoclaves Fully Automatic Double Wall Vertical


Enables reproducibility of results as full cycle including purging of stale air, sterilizing hold time, cycle end with exhaust of pressure is automatic, requiring no human intervention.
Widest options for documenting available:
Independent scanning, displaying and printing to inbuilt printer
Independent Strip chart recorder
Independent Chart Recorder
Supplied with Test Certificates & calibration reports along with traceablities for Temperature Controller and Pressure Gauge

Applications of Vertical Autoclaves


Fully Automatic Vertical Autoclaves are ideal for all critical applications requiring assured and reliable total destruction of all living microorganisms.
Ideal for Pharma QC / QA / Micro / R & D, Chemical Plants, Bio-Labs, Waste treatment, Water & Air Pollution Labs, Fisheries, Mineral Water, Food, Beverage & Distillery Plants, Flight Kitchens, Hotels, Hospitals, Nursing Homes, Polyclinics, specialty Doctors and all applications requiring assured sterilization.
Model
Working Chamber Size Ø x D in cm / Ltr.
PSI
Documenting Suffix
Carrier
(Ø x D) in cm
Net (kg)/Gr.(kg) / Volume(m3)
Independent
#7421FA 30x50 (12x20”)/35 15 CR: Plotting to inbuilt
Circular Chart Recorder
SP3: Scanning of 3 Temp. Ch.
o/p to inbuilt 18 col Printer
SP3P: Scanning of 3 Temp. Ch.
+ Pressure Ch. - o/p to inbuilt
18 col Printer
#SCRT4P: Strip Chart Recorder
(Point type) 4 temperature
&1 pressure channel
1 of 25x45 40 / 80 / 0.48
#7423FA 30x50 (12x20”)/35 30 1 of 25x45 45 / 85 / 0.48
#7431FA 35x55 (14x22”)/53 15 1 of 30x50 45 / 85 / 0.58
#7433FA 35x55 (14x22”)/53 30 1 of 30x50 50 / 90 / 0.58
#7441FA 45x71 (18x28”)/113 15 2 of 40x33 86 / 145 / 1.16
#7443FA 45x71 (18x28”)/113 30 2 of 40x33 91 / 150 / 1.16
#7451FA 55x76 (22x30”)/180 15 2 of 50x35 117 / 200 / 1.42
#7453FA 55x76 (22x30”)/180 30 2 of 50x35 122 / 205 / 1.42
Build your own custom featured Autoclave: 1st six digits for model & next two to eight for accessories (CR / SP3 / SP3P / SCRT4P)
For example #7441FACR = A Fully Automatic Autoclave of size 45 Ø x 71 cm + Chart Recorder.

Standard Features of Double Wall Fully Digital Automatic Autoclaves


Electrical and Electronics
µProcessor based Controller with time and temperature programmable by user.
A backlit alphanumeric two line 32 characters LCD display, displays all information including process and set values at a glance, eliminating guesswork.
Operating and Display range up to 122 C (135 C for models #7423 & #7433) in 0.1 C resolution.
Flexible Pt100 sensor, enabling precise in load monitoring.
Low water level alarm and cut off.
Sensor open alarm.
End of cycle buzzer and auto reset.
Miniature Circuit Breaker for On/Off plus safety.
Solenoid Valve for automatic purging and exhaust.
Industrial grade energy efficient ring type heater, custom made for EQUITRON Autoclaves, thus reducing power bills by 16 to 40%.

Mechanical
Lid is fitted with Pressure Gauge, Safety Valve, Extra Safety Valve, Manual Exhaust Valve, Vacuum Breaker cum Purge Valve and Quick Release Coupling for online pressure calibration checks.
Handy-raise device for lid - safe and user friendly - on #7441 and #7451.
Drain valve facilities easy cleaning.
Moulded rubber Gasket.
Stainless Steel carrier(s) along with heater cover stand.

Independent Documenting Options for Automatic Automatic Autocalves

Chart Recorder Circular

Chart Recorder - Circular
Independent online plotting of one flexible sensor - allows in-situ monitoring.
At-a-glance - easy & quick readablity.
Small 150mm - easy to handle circular chart size.
Plotting temperature range 90° to 140°C - enables 1 C readablity & eliminates ambiguity.
Fast motor of 4 hours / 1 revolution enables a meaningful plot length, while at the same time is sufficient to accommodate at least twoplots if desired

Scanner 3 Temperature Channels 18 Columns DMP

Scanner 3 Temperature Channels 18 Columns DMP
Independent scanning of three flexible sensors - allows in-situ monitoring and printing.
Built-in 18 column impact printer - uses normal calculator paper roll - thus saving on paper costs as well as giving a long shelf life of data.
Scans through the three temperature channels at preset time intervals.
Prints online every one minute with time and date.

Scanner  3 temperature channels  plus 1 Pressure channel with built in 18 column DMP

Scanner - 3 temperature channels + 1 Pressure channel - with built in 18 column DMP
Independent scanning of three flexible sensors plus one pressure sensor - allows in-situ monitoring and printing.
Built-in 18 column impact printer - uses normal calculator paper roll - thus saving on paper costs as well as giving a long shelf life of data.
Scans through the channels at preset time intervals.
Prints online every one minute with time and date.

Strip Chart Recorder (Point type) 4 temperature and 1 pressure channel
Strip Chart Recorder (Point type) 4 temperature and 1 pressure channel

Strip Chart Recorder (Point type) 4 temperature and 1 pressure channel
The #SCRT4P is a compact recorder with a recording width of 100mm.
Independent documenting by point method of 4 temperature & 1 pressure channels.
The Recorder has a high speed of 6 dot / 10 sec.
Highly reliability due to heavy duty voltage semiconductor.
Pen servo unit uses ultra-small stepping motors.
The measured value, channel number, alarm status and date/ time display are provided with 7 segments LED display.